Current Problems in Diagnostic Radiology
Volume 38, Issue 1 , Pages 33-43 , January 2009

Vascular Closure Devices: A Comparative Overview

  • Lye-Quen Hon, MB BCh, MRCP (UK), FRCR

      Affiliations

    • Royal Hallamshire Hospital, Sheffield, United Kingdom
    • Corresponding Author InformationReprint requests: Lye-Quen Hon, MB BCh, MRCP (UK), FRCR, C Floor Radiology Department, Royal Hallamshire Hospital, Sheffield S10 2 JF, United Kingdom
  • ,
  • Arul Ganeshan, BSc, MB BCh, MRCP (UK), FRCR

      Affiliations

    • John Radcliffe Hospital, Oxford, United Kingdom
  • ,
  • Steven Mark Thomas, MB BS, MRCP (UK), FRCR, MSc

      Affiliations

    • Sheffield Vascular Institute, Northern General Hospital, Sheffield, United Kingdom
  • ,
  • Dinuke Warakaulle, MB BS, MRCP (UK), FRCR

      Affiliations

    • Stoke Mandeville Hospital, Buckinghamshire, United Kingdom
  • ,
  • Jagalpathy Jagdish, MB BS, MRCPCH (UK)

      Affiliations

    • Royal Hallamshire Hospital, Sheffield, United Kingdom
  • ,
  • Raman Uberoi, BSc, MB BChir, MRCP (UK), FRCR

      Affiliations

    • John Radcliffe Hospital, Oxford, United Kingdom

References 

  1. Abbott WM, Austen WG. The effectiveness and mechanism of collagen-induced topical hemostasis. Surgery. 1975;78:723–729
  2. Hoffer EK, Bloch RD. Percutaneous arterial closure devices. JVIR. 2003;14:865–886
  3. Katz SG, Abando A. The use of closure devices. Surg Clin North Am. 2004;84:1267–1280
  4. Hatfield MK, Zaleski GX, Kozlov D, et al. Angio-seal device used for hemostasis in the descending aorta. AJR. 2004;183:612–614
  5. Blanc R, Mounayer C, Piotin M, et al. Hemostatic closure device after carotid puncture for stent and coil placement in an intracranial aneurysm: technical note. AJNR Am J Neuroradiol. 2002;23:978–981
  6. Micha JP, Goldstein BH, Lindsay SF, et al. Subclavian artery puncture repair with Angio-Seal deployment. Gynecol Oncol. 2007;104:761–763
  7. On-Site Precision Closure device, instructions for use.
  8. Mooney MR, Ellis SG, Gershony G, et al. Immediate sealing of arterial puncture sites after cardiac catheterization and coronary interventions: initial U.S. feasibility trial using the Duett vascular closure device. Catheter Cardiovasc Interv. 2000;50:96–102
  9. Michalis LK, Rees MR, Patsouras D, et al. A prospective randomised controlled trial comparing the safety, efficacy of 3 commercially available closure device (Angio-seal, Vasosea and Duett). Cadiovasc Intervent Radiol. 2002;25:423–429
  10. Shammas NW, Rajendran VR, Alldredge SG, et al. Randomized comparison of Vasoseal and Angio-Seal closure devices in patients undergoing coronary angiography and angioplasty. Catheter Cardiovasc Interv. 2002;55:421–425
  11. Haas PC, Krajcer Z, Diethrich EB. Closure of large percutaneous access sites using the Prostar XL percutaneous vascular surgery device. J Endovasc Surg. 1999;6:168–170
  12. Sanborn TA, Ogilby JD, Ritter JM, et al. Reduced vascular complications after percutaneous coronary interventions with a non mechanical suture device: Results from the randomized RACE study. Catheter Cardiovasc Interv. 2004;61:327–332
  13. Mehta H, Fleisch M, Chatterjee T, et al. Novel femoral artery puncture closure device in patients undergoing interventional and diagnostic cardiac procedures. Invasive Cardiol. 2002;14:9–12
  14. Eggebrecht H, Naber C, Woertgen U, et al. Percutaneous suture-mediated closure of femoral access sites deployed through procedure sheath: initial clinical experience with a novel vascular closure device. Catheter Cardiovasc Interv. 2003;58:313–321
  15. Park Y, Roh HG, Choo SW, et al. Prospective comparison of collagen plug (Angio-Seal) and suture mediated (Closer S) closure devices at femoral access sites. Korean J Radiol. 2005;6:248–255
  16. Caputo RP, Ebner A, Grant W, et al. Percutaneous femoral arteriotomy repair: initial experience with a novel staple closure device. J Invasive Cardiol. 2002;14:652–656
  17. Ansel G, Yakubov S, Nielson C, et al. Safety and efficacy of staple mediated femoral arteriotomy closure: Results from a randomised multicentre study. Catheter Cardiovasc Interv. 2006;67:545–553
  18. Hermiller J, Simonton C, Hinohara T, et al. Clinical experience with a circumferential clip based vascular closure device in diagnostic catheterisation. J Invasive Cardiol. 2005;17:504–510
  19. Hermiller J, Simonton C, Hinohara T, et al. The Starclose vascular closure system. Catheter Cardiovasc Interv. 2006;68:677–683
  20. Ratnam LA, Raja J, Munneke GJ, et al. Prospective nonrandomized trial of manual compression and AngioSeal and StarClose. Cardiovasc Intervent Radiol. 2007;30:182–188
  21. Doyle BJ, Godfrey MJ, Lennon RJ, et al. Initial experience with Cardiva Boomerang Vascular Closure Device in diagnostic catheterization. Catheter Cardiovasc Interv. 2007;16:203–208
  22. Lasic Z, Nikolsky E, Kesanakurthy S, et al. Vascular closure devices: A review of their use after invasive procedures. Am J Cardiovasc Drugs. 2005;5:185–200
  23. Koreny M, Riedmuller E, Nikfardjam M, et al. Arterial puncture closing devices compared with standard manual compression after cardiac catheterization: Systematic review and meta-analysis. JAMA. 2004;291:350–357
  24. Nikolsky E, Mehran R, Halkin A, et al. Vascular complications associated with arteriotomy closure devices in patients undergoing percutaneous coronary procedures: A meta-analysis. J Am Coll Cardiol. 2004;44:1200–1209
  25. Brown DB. Current status of suture mediated closure: What is the cost of comfort?. JVIR. 2003;14:677–681
  26. Resnic FS, Arora N, Matheny M, et al. A cost-minimization analysis of the angio-seal vascular closure device following percutaneous coronary intervention. Am J Cardiol. 2007;99:766–770
  27. Geyik S, Yavuz K, Akgoz A, et al. The safety and efficacy of the Angio-Seal closure device in diagnostic and interventional neuroangiography setting: a single-center experience with 1,443 closures. Neuroradiology. 2007;49:739–746