Saline Chasing Technique with Dual-Syringe Injector Systems for Multi-Detector Row Computed Tomographic Angiography: Rationale, Indications, and Protocols

  • Mark A. Auler, MD

      Affiliations

    • Department of Radiology, Medical University of South Carolina, Charleston, SC
  • ,
  • Terry Heagy, RT

      Affiliations

    • Medrad Inc., Pittsburgh, PA.
    • T.H. is an employee of Medrad Inc., Pittsburgh, PA. U.J.S. received a research grant provided by Medrad.
  • ,
  • Lejla Aganovic, MD

      Affiliations

    • Department of Radiology, Medical University of South Carolina, Charleston, SC
  • ,
  • Robin Brothers, RT

      Affiliations

    • Department of Radiology, Medical University of South Carolina, Charleston, SC
  • ,
  • Philip Costello, MD

      Affiliations

    • Department of Radiology, Medical University of South Carolina, Charleston, SC
  • ,
  • U. Joseph Schoepf, MD

      Affiliations

    • Department of Radiology, Medical University of South Carolina, Charleston, SC
    • Corresponding Author InformationReprint requests: U. Joseph Schoepf, MD, Department of Radiology, Medical University of South Carolina, 169 Ashley Avenue, Charleston, SC 29425.

References 

  1. Hopper KD , Mosher TJ , Kasales CJ , et al.   Thoracic spiral CT (delivery of contrast material pushed with injectable saline solution in a power injector) . Radiology . 1997;205:269–271
  2. Schoellnast H , Tillich M , Deutschmann HA , et al.   Improvement of parenchymal and vascular enhancement using saline flush and power injection for multiple-detector-row abdominal CT . Eur Radiol . 2004;14:659–664
  3. Coche EE , Hammer FD , Goffette PP . Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT . Eur Radiol . 2001;11:2306–2309
  4. Haage P , Schmidz-Rode T , Hubner D , et al.   Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax . AJR . 2000;174:1049–1053
  5. Cademartiri F , van der Lugt A , Luccichenti G , et al.   Parameters affecting bolus geometry in CTA (A review) . J Comput Asst Tomogr . 2002;26:598–607
  6. Schoellnast H , Tillich M , Deutschmann HA , et al.   Abdominal multidetector row computed tomography (reduction of cost and contrast material dose using saline flush) . J Comput Assist Tomogr . 2003;27:847–853
  7. Dorio PJ , Lee FT , Hensler KP , et al.   Using a saline chaser to decrease contrast media in abdominal CT . AJR . 2003;180:929–934

PII: S0363-0188(05)00061-7

doi: 10.1067/j.cpradiol.2005.10.001

Current Problems in Diagnostic Radiology
Volume 35, Issue 1 , Pages 1-11 , January 2006